Kalstein

Biosafety Cabinet YR06543: A Comprehensive Overview

By Kalstein · Published on:

Category:articulos-de-productos

Biosafety Cabinet YR06543: A Comprehensive Overview

Explore the features, benefits, and specifications of the YR06543 biosafety cabinet, a cutting-edge solution for laboratory safety.

Biosafety Cabinet YR06543: A Comprehensive Overview

Biosafety Cabinet YR06543: A Comprehensive Overview

Product Description

The YR06543 biosafety cabinet is a state-of-the-art solution designed to protect personnel, products, and the environment through its negative pressure system which prevents leaks. Operating on a principle of 70% internal circulation and 30% external discharge, this cabinet is built with high-quality cold-rolled steel and features a work surface made of corrosion-resistant physico-chemical plates. Precision CNC laser cutting and electrostatic epoxy resin surface treatment ensure durability and longevity.

The system integrates intelligent control with an LCD touchscreen that provides an intuitive understanding of operational status. The cabinet complies with international standard ISO14644.1 Class 5, equivalent to US Federal Standard 209E, Class 100.

Motor: The cabinet adopts a high-efficiency EBM German motor known for high airflow and low energy consumption, optimized to minimize turbulence concentration and ensure uniform airflow.

Filtration: The YR06543 is equipped with high-efficiency external HEPA filters and ultra-low penetration air (ULPA) filters to provide superior air quality control.

Market Price

ModelPrice (USD)Weight (Kg)Dimensions (mm)
YR065431720.00250900 x 760 x 2250
YR06544UnknownUnknown1100 x 760 x 2250
YR06545UnknownUnknown1300 x 760 x 2250
YR06546UnknownUnknown1500 x 760 x 2250
YR06547UnknownUnknown1800 x 760 x 2250

Frequently Asked Questions

What is the difference between ULPA and HEPA filters?

The G series uses ultra-high-efficiency ULPA filters (99.999% efficiency), while the D series utilizes high-efficiency HEPA filters (99.995% efficiency). Both are excellent, but ULPA offers a slightly higher level of purity.

What is the accuracy of the downward airflow control?

The accuracy of the downward airflow control is 0.015 m/s, ensuring uniformity and stability of flow to maintain sterility in the workspace.

What sizes are available for the YR06543?

The YR06543 model comes in various sizes, specifically designed for different laboratory requirements. The external dimensions range from 900 mm to 1800 mm in length.

What level of cleanliness does the cabinet guarantee?

The cabinet guarantees a level 5 cleanliness according to international standard ISO14644.1 (Class 100 US Federal 209E), which is a strict requirement for sensitive environments.

What are the environmental requirements for the YR06543?

The working environment must be maintained between 10 and 30°C with a relative humidity below 70% to ensure optimal performance.

How often should maintenance be performed on the filters?

Regular maintenance on the filters is essential to ensure long-term performance and safety. Filters should be checked and replaced as necessary based on usage and air quality conditions.

What is the weight of the YR06543 model?

The shipping weight of the YR06543 model is considerable, ranging from 138 kg to 198 kg depending on the size, which can complicate transport and installation.

Pros and Cons

Pros:

  • Double filtration: Utilizes external HEPA filters and ULPA/HEPA downflow filters, ensuring up to 99.999% efficiency.
  • Superior safety (negative pressure): The negative pressure design prevents leaks, thus protecting both the operator and the environment.
  • Optimized design: Air ducts and negative pressure box are optimized for flow uniformity.
  • High-performance German motor: Utilizes an EBM motor known for low consumption and high air volume.
  • Durable construction: Made with corrosion-resistant cold-rolled steel and epoxy resin surface treatment.

Cons:

  • Environmental requirements: The working environment must be maintained between 10 and 30°C with relative humidity below 70%.
  • Shipping weight: The weight of shipping is considerable, which may complicate transport and installation.
  • Flow limitations: Although it is a recirculation system (70% internal), the 30% external discharge requires an exhaust ventilation system.

Field Usage

The Type A2 Class II biosafety cabinet is essential for handling biological agents of low to moderate risk, such as viruses, bacteria, and cell cultures that require biosafety. It is the standard choice in microbiology laboratories, hospitals, and biotechnology and pharmaceutical research centers, where the protection of products, personnel, and the environment is crucial. Its vibration control capabilities (mean wave: 3 μm) and stable airflow are vital for delicate experiments.

Recommendations

To ensure longevity and maximum safety, it is recommended to:

  • Perform regular maintenance on the filters and check the calibration of the imported sensor.
  • Ensure the working environment meets the temperature (10-30 °C) and humidity (below 70%) requirements.
  • Regularly check the inlet airflow speed (average 0.53 m/s to 0.56 m/s) and the downward airflow speed (average 0.35 m/s) to ensure the effectiveness of negative pressure protection.
  • Use heavy-duty wheels for initial positioning and ensure stability before use.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Biosafety cabin YR06543 with all specifications, dimensions, accessories and quote options.
View product datasheet →