The YR436-1 Fully Automated Slide Stainer is designed to optimize and automate the staining process in histology and pathology laboratories. This compact and low-noise system uses imported high-quality materials and elements, ensuring stable operation and reliable performance. Its intuitive touchscreen interface allows for easy operation, facilitating communication between the user and the machine. The robust APS-coated housing is streamlined, easy to clean, and highly resistant to corrosion, ensuring long-lasting durability. The YR436-1 can process 24 runs simultaneously with a rapid staining process. This device features an intelligent automatic inflow, outflow, and drainage system, ensuring efficient washing performance at each step and improving water usage efficiency.

This page provides an overview of the Automated slide staining YR436-1, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.

This Kalstein model is available for laboratories in Pakistan, with selection criteria adapted to local purchasing, installation and support conditions.

Ver más

Key factors to consider

Key factors to consider

Before selecting the Automated slide staining YR436-1, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.

In practical applications, the YR436-1 Fully Automated Slide Stainer is used for efficient and precise slide staining in histology and pathology laboratories. Its ability to process 24 runs simultaneously and its protocol programming system make it ideal for laboratories with high workloads. The ability to optionally stop or immerse the slide rack in a cup according to the user's selection, with an audible alert upon completion, significantly enhances workflow efficiency.

For the market in Pakistan, evaluation should consider local context such as public health, textile/agro labs, DRAP regulation and match the product to the real workload of the laboratory.

Market price range

Market price range

The price of the YR436-1 Fully Automated Slide Stainer varies depending on the supplier and additional specifications. Generally, these high-quality systems range from $6,000 to $8,500 USD. This investment reflects the advanced technology and precise features of the YR436-1, making it a valuable option for laboratories seeking consistent and high-quality results.

The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.

In Pakistan, budget comparison should include DRAP references, 230V/50Hz power conditions, accessories, logistics and after-sales support.

Value for money

Value for money

Advantages: Fully automated computer control. Capacity to program and store multiple staining protocols. Automatic inflow/outflow/drainage system that improves water efficiency. Intuitive and easy-to-use touchscreen interface. Low noise and stable operation. Disadvantages: It may require a significant initial investment. Its size can be a challenge for laboratories with limited space.

Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.

Advantages and disadvantages

Advantages and disadvantages

In practical applications, the YR436-1 Fully Automated Slide Stainer is used for efficient and precise slide staining in histology and pathology laboratories. Its ability to process 24 runs simultaneously and its protocol programming system make it ideal for laboratories with high workloads. The ability to optionally stop or immerse the slide rack in a cup according to the user's selection, with an audible alert upon completion, significantly enhances workflow efficiency.

Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.

Expected lifespan based on use and maintenance

Expected lifespan based on use and maintenance

To ensure the optimal performance of the YR436-1, it is recommended to follow the manufacturer's instructions for regular maintenance and equipment calibration. Properly training personnel in the correct use of the system is also essential to achieve consistent results and extend the device's lifespan. Discover how the YR436-1 Fully Automated Slide Stainer can improve efficiency and precision in your laboratory. Request a personalized quote or generate an automatic quote through Kalstein Plus today. Elevate the quality of your sample processing and optimize your workflow with our advanced laboratory solutions.

Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.

Support and spare-parts availability oriented to Pakistan helps preserve service continuity and plan preventive maintenance without extended downtime.

Specifications table for the Automated slide staining YR436-1

Automated slide staining YR436-1

Automated slide staining YR436-1

Sistema de transmisión flexible de bajo ruido y resistente al desgaste utilizando materiales y elementos importados de alta calidad para garantizar un funcionamiento estable y un rendimiento confiable.

  • Con su pequeña huella, este mini dispositivo compacto se puede colocar cerca del área de la sección para un flujo de trabajo óptimo

  • Con su interfaz de pantalla táctil intuitiva y su conveniente comunicación entre el hombre y la máquina, la operación es fácil de aprender y fácil de usar.

  • Pantalla táctil integrada con un sistema de control intuitivo altamente inteligente ofrece un conjunto completo de funciones, rendimiento confiable y operación fácil

  • La robusta carcasa recubierta de APS, simplificada, fácil de limpiar y altamente resistente a la corrosión.

  • 24 carreras se pueden manchar simultáneamente con un proceso de tinción rápida

  • El bastidor de diapositivas se puede detener o sumergir opcionalmente en una copa según la selección de usuario después de completar el proceso de tinción, con un pitido para alertar al usuario

  • Permitir que este dispositivo sea una opción ideal para la tinción H & E

  • Sistema de transmisión flexible de bajo ruido y desgaste que utiliza materiales y elementos importados de alta calidad para garantizar un funcionamiento estable y un rendimiento confiable

  • Sistema inteligente de flujo de entrada / salida / drenaje automático que garantiza un rendimiento de lavado suficiente en cada paso y mejora la eficiencia del agua

  • Se pueden programar y almacenar 25 juegos de protocolos de tinción en el sistema con cada protocolo que contiene 30 pasos editables para la tinción

  • Operación de alerta de error


ModelYR436-1
(current)
Number of tanks15 (station 1 is for drying, station 2 for washing, and the other 13 stations for reagents)
Capacity of each tankaround 350ml
Treatment duration in the tank.adjustable between 0 and 59 minutes and between 0 and 59 seconds
Temperature control accuracy± 1%
Drip timeadjustable between 0 and 60 seconds
Stirring frequencyadjustable between 0 and 6 times/minute
Operating voltageAC220V ± 10% 50Hz (standard model); AC 110 V ± 10 % 60 Hz
Power400W
Dimensions925 × 250 × 260 mm (L × W × H)
Weight27 kg
View product

Products related to model YR436-1

Frequently Asked Questions about the Automated slide staining YR436-1

How many tanks does the YR436-1 have?

The YR436-1 has 15 tanks: station 1 is for drying, station 2 is for washing, and the other 13 stations are for reagents.

Is the YR436-1 easy to operate?

Yes, its intuitive touchscreen interface and ergonomic design make both operation and maintenance straightforward.

How do I choose the right automated slide staining yr436-1 for my laboratory?

Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.

What should I review before requesting a quotation?

Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.

Does Kalstein provide guidance for this type of equipment?

Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.

What maintenance helps extend the equipment lifespan?

Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.