Kalstein

Technical Glossary and Key Terminology of the YR01815-1 Pocket Salinity Meter

By Kalstein · Published on:

Category:articulos-de-productos

Technical Glossary and Key Terminology of the YR01815-1 Pocket Salinity Meter

Explore the technical glossary and key terminology associated with the YR01815-1 Pocket Salinity Meter for a deeper understanding of its features and applicatio

Technical Glossary and Key Terminology of the YR01815-1 Pocket Salinity Meter

Technical Glossary and Key Terminology of the YR01815-1 Pocket Salinity Meter

The YR01815-1 Pocket Salinity Meter is an essential tool in various scientific fields. Understanding its technical terminology enhances the user experience and ensures accurate application and interpretation of results. This article provides a comprehensive glossary of key terms associated with the YR01815-1 model, alongside insights into its operation, features, and applications.

Overview of the YR01815-1 Pocket Salinity Meter

The YR01815-1 Pocket Salinity Meter is designed for low-range salinity measurements. With calibration options ranging from 1 to 3 points, it provides precise readings essential for various applications. The device incorporates a platinum conductivity cell, ensuring rapid and reliable measurements. Automatic temperature compensation further ensures accuracy across the specified range.

Technical Specifications

FeatureSpecification
ModelYR01815-1
Salinity Range0.00 to 10.00 ppt
Resolution0.01 ppt
Accuracy±1% F.S.
Conductivity Range0 to 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
Calibration Points1 to 3 points
Temperature Range0 to 60°C / 32 to 140°F
Power Supply2 AAA 1.5V batteries
Battery LifeApproximately 200 hours of continuous use
Dimensions185(L) × 40(Dia.) mm
Weight100 g

Glossary of Key Terms

Understanding specific terminology related to the YR01815-1 enhances usability and efficiency in various applications. Below is a glossary of essential terms:

TermDefinition
SalinityThe concentration of salts in water, usually measured in parts per thousand (ppt).
ConductivityThe ability of water to conduct electricity, which correlates with the concentration of ions in the water.
CalibrationThe process of configuring an instrument to provide a result for a sample within an acceptable range.
Automatic Temperature Compensation (ATC)A feature that allows the meter to adjust readings based on the temperature of the sample, ensuring accuracy.
PPTParts per thousand, a measurement unit used to express salinity.
ResolutionThe smallest change in a quantity that can be detected by the instrument.
AccuracyThe degree to which a measured value reflects the actual value.
ElectrodeA conductor through which electricity enters or leaves the medium, critical for conductivity measurements.
Pocket MeterA portable meter designed for on-the-go measurements, suitable for field use.
DisplayThe interface showing measurement results, usually in digital format.
Power SupplyThe source providing electrical power to the device.
Battery LifeThe duration for which the meter can operate on a single set of batteries.
Water-ResistantA design feature that protects the instrument from water intrusion, allowing use in wet conditions.
MaintenanceRegular checks and servicing to ensure the instrument remains functional and accurate.
Electrochemical SensorA type of sensor that measures conductivity based on the electrochemical properties of a solution.
Calibration SolutionsStandard solutions used to calibrate the meter, ensuring accuracy in measurements.

Frequently Asked Questions

What is the calibration process for the YR01815-1 Pocket Salinity Meter?

The calibration process involves selecting the number of calibration points on the device, using standard solutions to adjust the readings. Following the manufacturer's instructions ensures precise calibration, crucial for accurate measurements.

How does automatic temperature compensation work in the YR01815-1?

Automatic temperature compensation (ATC) in the YR01815-1 allows the meter to make real-time adjustments to readings based on the temperature of the sample. This ensures that variations in temperature do not affect the accuracy of the salinity measurements.

What are the applications of the YR01815-1 Pocket Salinity Meter?

The YR01815-1 is suitable for various applications, including water quality testing in environmental studies, aquaculture, and laboratories where precise salinity measurements are required.

How do I replace the batteries in the YR01815-1?

To replace the batteries, locate the battery compartment on the meter, open it, remove the old batteries, and insert new AAA batteries, ensuring the correct polarity. Close the compartment securely before use.

What should I do if the readings from the YR01815-1 seem inaccurate?

If readings appear inaccurate, first check the calibration status and perform calibration if necessary. Ensure that the electrode is clean and properly inserted into the solution. If issues persist, consult the troubleshooting section of the user manual.

Is the YR01815-1 Pocket Salinity Meter water-resistant?

Yes, the YR01815-1 is designed with water-resistant features, making it suitable for use in wet environments while ensuring protection against water damage.

If you are interested in purchasing the YR01815-1 Pocket Salinity Meter or have any inquiries, feel free to request a quote on Kalstein Plus.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Pocket Salinity Meter YR01815-1 with all specifications, dimensions, accessories and quote options.