Description
The Electrolyte Analyzer YR06396 // YR06406 is an advanced device designed to provide fast and accurate measurements of electrolytes in serum, plasma, whole blood, and diluted urine samples. Equipped with automatic electric potential tracking and correction software, it ensures stable performance. This analyzer effectively detects and filters tiny bubbles to prevent clogging and guarantee precise measurements. Real-time diagnosis of the system’s working status and automatic detection of waste liquid, along with corresponding alarms, enhance operational safety. The instrument also features automatic calibration and two-point correction for slope and intercept adjustments, ensuring accuracy.
Utilizing wave flushing and direct flushing pipe methods, the YR06396 // YR06406 minimizes blockages and cross-contamination risks. With power failure protection, it can store up to 10,000 test results, while its minimal consumption helps reduce consumable costs. The measuring time is less than 30 seconds, making it highly efficient for busy clinical environments. Additionally, the analyzer supports a variety of test parameters including K, Na, Cl, iCa, nCa, TCa, pH, TCO₂, AG, Li, and Mg, providing comprehensive electrolyte analysis.
Market Price
The price of the Electrolyte Analyzer YR06396 // YR06406 ranges between $2000 and $7000 USD, depending on additional features and the supplier. This investment reflects the advanced technology and precision of the equipment. To obtain a personalized quote tailored to your laboratory’s specific needs, visit the Kalstein Plus platform. There, you can quickly and easily generate an automatic quote, optimizing your investment in high-quality equipment.
Frequently Asked Questions
- What types of samples can the YR06396 // YR06406 analyze?
This analyzer can measure electrolytes in serum, plasma, whole blood, and diluted urine samples. - What is the storage capacity of the YR06396 // YR06406?
The device can store up to 10,000 test results. - How long does it take to perform a measurement?
The YR06396 // YR06406 performs measurements in less than 30 seconds.
Advantages And Disadvantages
Advantages:
- High precision and speed in measurements.
- Interactive menu with real-time display.
- Automatic bubble detection and advanced flushing methods.
- Large storage capacity for results.
- Power failure protection.
Disadvantages:
- Significant initial cost, which can be a considerable investment for some laboratories.
- Requires regular maintenance to ensure optimal performance.
Field Use
The YR06396 // YR06406 is ideal for clinical and hospital laboratories that need to perform rapid and precise electrolyte analysis. Its ability to handle multiple types of samples and its efficient design make it perfect for high-demand environments. Laboratories can benefit from its fast measurement speed and ease of use, ensuring consistent and reliable results in every test.
Recommendations
To maximize the performance of the Electrolyte Analyzer YR06396 // YR06406, it is essential to follow the manufacturer’s recommendations for maintenance and calibration. Perform periodic inspections and keep the system clean to prevent build-ups that could affect accuracy. Additionally, adequately train personnel in the use of the instrument to ensure efficient operation and prolong the equipment’s lifespan.
To enhance your laboratory capabilities and obtain a reliable and precise electrolyte analysis device, consider the Electrolyte Analyzer YR06396 // YR06406. Visit the Kalstein Plus platform to request a personalized quote or generate an automatic quote today. Don’t miss the opportunity to optimize your laboratory with this advanced technology.
Technical Specifications
Model | YR06396 | YR06397 | YR06398 | YR06399 | YR06400 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Analysis Method | ion selective electrode(ISE) | ||||
Measuring time | ≤30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Temperature | 10-30°C | ||||
Relative Humidity | 80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na CI TCO, AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO₂ AG | K Na Cl Li |
Model | YR064001 | YR06402 | YR06403 | YR06404 | YR06405 | YR06406 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Analysis Method | ion selective electrode(ISE) | |||||
Measuring time | ≤30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Temperature | 10-30°C | |||||
Relative Humidity | 80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li TCO₂ AG |
K Na Cl iCa nCa TCa pH Mg Li
|
Accessories
Model | Description |
YRA264 | K Electrode |
YRA265 | K Electrode |
YRA266 | Cl Electrode |
YRA267 | Ca Electrode |
YRA268 | pH Electrode |
YRA269 | Li Electrode |
YRA270 | Mg Electrode |
YRA271 | Ref. Electrode |
YRA272 | Reagent Pack Calibration A 430ml; Calibration B 110ml; ( For Model H900 only) |
YRA273 | Reference Electrode Internal Solution – 10ml |
YRA274 | Electrode Internal
Solution – 3ml |
YRA275 | Activating Solution – 110ml |
YRA276 | QC Solution Level 2
(Water-based) – 110ml |
YRA277 | Cleaning Solution – 110ml |
YRA278 | Electrode Wash Solution (Protein Enzyme) -125mg (25mg/bottle x5) |
YRA278-1 | Electrode Wash Solution (Diluent) – 5ml ( 1 bottle) |