Understanding Measurements and Results Interpretation with the YR05315-1 Ultra Low Temperature Freezer
The YR05315-1 Ultra Low Temperature Biomedical Horizontal Freezer is a vital tool used in hospitals and laboratories for the preservation of various biological samples and reagents. Understanding how to correctly interpret measurements and results from this equipment is crucial for ensuring optimal performance and accuracy. This article delves into the specific functionalities of the YR05315-1, focusing on how to read and interpret its measurements effectively.
Technical Data for the YR05315-1
| Specification | Detail |
|---|---|
| Model | YR05315-1 |
| Performance | |
| Cooling Method | Direct Cooling |
| Defrosting | Manual |
| Temperature Range | -25°C ~ -60°C |
| Ambient Temperature | 10~32°C |
| Noise Level (db) | 53 |
| Cooling System | |
| Refrigerant | R4001 |
| Temperature Controller | Microprocessor |
| Sensor | NTC |
| Display | Digital Display |
| Exterior Material | SPCC Powder-coated Steel |
| Compressor Count | CUBIGEL/1 |
| Alarms | |
| High/Low Temperature Alarm | Yes |
| Power Failure Alarm | Yes |
| Sensor Error Alarm | Yes |
| Controller Failure Alarm | Yes |
| Door Ajar Alarm | Yes |
| Backup Power in Case of Electrical Failure | 12 hours |
| Electrical Data | |
| Voltage Frequency (V/Hz) | 220V 50Hz |
| Power (W) | 600W |
| Current (A) | 3.44A |
| Energy Consumption | 7.45 kWh/24 h |
| Dimensions | |
| Capacity (L/Cubic foot) | 485/17.12 |
| Exterior Size (WxDxH) (mm) | 1670*810*930 |
| Interior Size (WxDxH) (mm) | 1455*525*665 |
| Other | |
| Inner Door | / |
| Remote Alarm Port | Optional |
| Access Port CANT/Dia. | 1/25 mm |
| Internal Material | SPCC Powder-coated Steel |
Understanding the Measurement System in YR05315-1
Key to the effective use of the YR05315-1 is familiarity with its measurement system. The digital display presents temperature readings in Celsius, providing real-time information on the internal environment of the freezer. A temperature control accuracy of ±0.1°C ensures that samples are maintained at their required temperatures without significant fluctuation.
Common Terminology Used in Measurements
For effective interpretation, it is essential to understand the terminology associated with the YR05315-1. Terms such as 'ambient temperature,' 'defrost cycle,' and 'refrigerant type' are crucial to comprehending the device's operational efficiency and the conditions under which it should be used.
Steps for Accurate Measurement Interpretation
Accurate measurement interpretation involves several steps:
- Regularly calibrate the temperature sensor to maintain measurement accuracy.
- Ensure that the freezer is not overloaded, as this can lead to inaccurate temperature readings.
- Monitor the set point temperature against the actual temperature, adjusting as needed to ensure compliance with storage requirements.
Common Issues and Solutions Related to Measurements
Even with careful monitoring, issues may arise that affect the accuracy of measurements. Below is a table of common symptoms, their probable causes, and solutions.
| Symptom | Probable Cause | Solution |
|---|---|---|
| Temperature reading fluctuates | Overloading or insufficient airflow | Remove excess items and ensure proper ventilation. |
| Alarm sounds frequently | High ambient temperature or power failure | Check the external environment and restore power. |
| Inconsistent readings | Sensor malfunction | Calibrate or replace the temperature sensor as necessary. |
Best Practices for Result Interpretation
To maximize the reliability of results obtained from the YR05315-1, the following best practices are recommended:
- Regularly check and update calibration settings based on environmental changes.
- Log temperature readings to monitor trends over time, helping identify potential issues.
- Train staff on proper use and interpretation of results to ensure consistent understanding among users.
Frequently Asked Questions
What temperature range does the YR05315-1 operate within?
The YR05315-1 operates within a temperature range of -25°C to -60°C, providing flexibility for various storage needs.
How often should the temperature sensor be calibrated?
It is recommended to calibrate the temperature sensor at least once every six months or whenever the unit is moved to a new location.
What actions should be taken if the alarm frequently activates?
If the alarm frequently activates, check the ambient temperature and inspect for any power interruptions. Ensure the freezer is not overstocked to allow for proper airflow and cooling.
How can I ensure accurate temperature readings?
To ensure accurate temperature readings, regularly maintain the device, avoid overloading it, and ensure proper ventilation around the unit.
What type of refrigerant does the YR05315-1 use?
The YR05315-1 utilizes R4001 refrigerant, which is effective and environmentally friendly.
What should I do if there is a power failure?
In case of power failure, the YR05315-1 has a backup power system that can maintain the internal environment for up to 12 hours. Ensure that you check the power restoration promptly.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.