Bedside Monitor YR02173

Pantalla táctil de 12,1 ECG de 5 derivaciones, PRAE, Temp (un canal), COMEN SpO2, PNI, FC Dual-IBP, EtCO2, AG, ICG, C.O., BIS, Nellcor/Masimo SpO2, ECG de 3/12 derivaciones, Registrador térmico, Dual-Temp, Suntech NIBP, Carro, Montaje en pared
This page provides an overview of the Bedside Monitor YR02173, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in Pakistan, with selection criteria adapted to local purchasing, installation and support conditions.
Key factors to consider

Before selecting the Bedside Monitor YR02173, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
Its use is oriented to laboratory routines that require observation, control and operational continuity.
For the market in Pakistan, evaluation should consider local context such as public health, textile/agro labs, DRAP regulation and match the product to the real workload of the laboratory.
Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In Pakistan, budget comparison should include DRAP references, 230V/50Hz power conditions, accessories, logistics and after-sales support.
Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

Modelo YR02173 ECG Modo principal 5 conductores (RA,LA,LL,RL,V) Método de conexión I, II, III,AVR,AVL,AVF,V Modo Plomo 3 conductores (RA,LA,LL) Método de conexión I, II,III Forma de onda 1ch Gane 1,25, 2,5, 5,0, 10, 20, 40mm/mV, Auto. Gama HR Adulto: 15~300bpm Neo/Ped 15~350bpm Precisión ±1% o ±1bpm Resolución 1bpm Sensibilidad 200(uVp-p) Impedancia de entrada diferencial ≥5MΩ Rango de monitorización del segmento ST Rango de medida -2,0~+2,0mV Medir la precisión -0,8mV~+0,8mV Frecuencia cardiaca Rango de medición 15~300bpm Precisión ±1bpm Resolución 1bpm Sensibilidad 200UVp-p Respiración Método Impedancia entre R-F(RA-LL) Impedancia de entrada diferencial 2,5MΩ Rango de impedancia de medición 0,3~3,0 MΩ Línea base Rango de impedancia 200~4000Ω Ancho de banda 0,1~2,5Hz Frecuencia…
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to Pakistan helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Bedside Monitor YR02173

Bedside Monitor YR02173
- Pantalla táctil de 12,1
- ECG de 5 derivaciones, PRAE, Temp (un canal), COMEN SpO2, PNI, FC
- Dual-IBP, EtCO2, AG, ICG, C.O., BIS, Nellcor/Masimo SpO2, ECG de 3/12 derivaciones, Registrador térmico, Dual-Temp, Suntech NIBP, Carro, Montaje en pared
| Modelo | YR02173 | |
ECG | Modo principal | 5 conductores (RA,LA,LL,RL,V) |
| Método de conexión | I, II, III,AVR,AVL,AVF,V | |
| Modo Plomo | 3 conductores (RA,LA,LL) | |
| Método de conexión | I, II,III | |
| Forma de onda | 1ch | |
| Gane | 1,25, 2,5, 5,0, 10, 20, 40mm/mV, Auto. | |
| Gama HR | Adulto: 15~300bpm | |
| Neo/Ped | 15~350bpm | |
| Precisión | ±1% o ±1bpm | |
| Resolución | 1bpm | |
| Sensibilidad | 200(uVp-p) | |
| Impedancia de entrada diferencial | ≥5MΩ | |
| Rango de monitorización del segmento ST | ||
| Rango de medida | -2,0~+2,0mV | |
| Medir la precisión | -0,8mV~+0,8mV | |
Frecuencia cardiaca | Rango de medición | 15~300bpm |
| Precisión | ±1bpm | |
| Resolución | 1bpm | |
| Sensibilidad | 200UVp-p | |
Respiración | Método | Impedancia entre R-F(RA-LL) |
| Impedancia de entrada diferencial | 2,5MΩ | |
| Rango de impedancia de medición | 0,3~3,0 MΩ | |
| Línea base Rango de impedancia | 200~4000Ω | |
| Ancho de banda | 0,1~2,5Hz | |
| Frecuencia respiratoria | Adulto: 2~120BrPM | |
| Neo/Ped | 0~150BrPM | |
| Resolución | 1 BrPM | |
| Precisión | ±2 BrPM | |
| Alarma | 10~40S | |
| NIBP | Método | Oscilométrico |
| Modo | Manual/Auto/STAT | |
| Intervalo de medición en modo AUTO | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
| Periodo de medición en modo STAT | 5 minutos | |
| Frecuencia de pulso | 40~240bpm | |
| Tipo de alarma | SYS, DIA, MEAN | |
| Resolución | ||
| Presión | 1mmHg | |
| Precisión | Error medio máximo: 5mmHg | |
| Máximo Desviación típica | 8mmHg | |
SPO2 | Mostrar | Número de SPO2,forma de onda de capacidad,Pulso |
| Rango de medición | 0~100% | |
| Resolución | 1% | |
| Precisión | 60~100% (±2%) | |
| Sistema de alarma | Alarma audio-vídeo | |
| Frecuencia de pulso | 0~300bpm | |
TEMP | Canal | 2 |
| Rango de medición y alarma | 0~50ºC | |
| Resolución | 0,1ºC | |
| Precisión | 0,1ºC | |
| Intervalo de actualización | Alrededor de 1 segundo. | |
| Constante de tiempo media | 10 segundos. | |
Frequently Asked Questions about the Bedside Monitor YR02173
How do I choose the right bedside monitor yr02173 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.